SensorCompatibility : Temperature, Pressure, CO2 Sensors

Payment Terms : T/T

Actuator Type : Modulating Damper Actuator

Delivery Time : 7 Days

Mounting Type : Duct or Wall Mounted

Certification : CE RoHS

Control Modes : Automatic KNX sensor linkage

Packaging Details : Carton

Application : HVAC Systems

Place of Origin : EU

Control Type : Variable Air Volume

MOQ : 5

Model Number : MNB-V1-2

Color : Light Grey

Brand Name : Schneider

Contact Now

MNB-V1-2 Schneider MN BACnet VAV Controller Pressure Independent Zone HVAC Damper Smart Building

The Schneider Electric MNB-V1-2 is a BACnet VAV controller designed for zone-level airflow management in smart building applications. This pressure-independent controller integrates seamlessly into BACnet/IP and MS/TP networks, utilizing advanced control algorithms to optimize comfort and energy efficiency.

Technical Specifications
Communication
  • Protocol: BACnet MS/TP (RS-485), BACnet/IP
  • Profile: B-AAC
  • Baud Rate: 9600-76800 bps
  • Objects: Up to 128
Inputs & Outputs
  • AI: 4 universal (0-10V/4-20mA/10k NTC)
  • DI: 4 dry contact (pulse counting)
  • AO: 2 x 0-10V for damper control
  • DO: 4 relay (2A @ 24VAC)
Hardware
  • Processor: 32-bit ARM with FPU
  • Memory: 512KB Flash, 128KB RAM
  • Power: 24VAC/DC +/-10%, 15VA
  • Operating Temperature: 0°C to 50°C
  • Mounting: DIN-rail or panel
  • I/O Expansion: Remote modules via MS/TP
Certifications BTL, CE, UL, FCC
Application Scenarios

Ideal for office buildings, hospitals, schools, and retail environments. The controller integrates with SmartX and EcoStruxure building management systems for comprehensive VAV box control with reheat, demand-controlled ventilation based on CO2 levels, and occupancy-based airflow management. Supports energy optimization strategies including optimal start/stop, night setback, holiday scheduling, and peak demand management.


Product Tags:

Schneider MN BACnet VAV controller

      

pressure independent HVAC damper

      

smart building VAV controller

      
Quality MNB-V1-2 Schneider MN BACnet VAV Controller Pressure Independent Zone HVAC Damper Smart Building wholesale

MNB-V1-2 Schneider MN BACnet VAV Controller Pressure Independent Zone HVAC Damper Smart Building Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Maituo Intelligent Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)